5-1 WATER Subparts 5-101 Source 5-102 Quality 5-103 Quantity and Availability 5-104 Distribution, Delivery, and Retention |
| Source |
Drinking water shall be obtained from an approved source that is:
A drinking water system shall be flushed and disinfected before being placed in service after construction, repair, or modification and after an emergency situation, such as a flood, that may introduce contaminants to the system.
|
|
Bottled drinking water used or sold in a food establishment shall be obtained from approved sources in accordance with 21 CFR 129 - Processing and Bottling of Bottled drinking water.
|
||
| Quality |
Except as specified under ' 5-102.12:
|
|
(A) A non-drinking water supply shall be used only if its use is approved. (B) Nondrinking water shall be used only for nonculinary purposes such as air conditioning, nonfood equipment cooling, fire protection, and irrigation.
|
||
Except when used as specified under ' 5-102.12, water from a nonpublic water system shall be sampled and tested at least annually and as required by state water quality regulations.
The most recent sample report for the nonpublic water system shall be retained on file in the food establishment or the report shall be maintained as specified by state water quality regulations.
|
||
Quantity and Availability |
(A) The water source and system shall be of sufficient capacity to meet the peak water demands of the food establishment. (B) Hot water generation and distribution systems shall be sufficient to meet the peak hot water demands throughout the food establishment.
|
|
Water under pressure shall be provided to all fixtures, equipment, and nonfood equipment that are required to use water except that water supplied as specified under && 5-104.12(A) and (B) to a temporary food establishment or in response to a temporary interruption of a water supply need not be under pressure if approved.
|
||
Distribution, Delivery, and Retention |
Water shall be received from the source through the use of:
|
|
Water meeting the requirements specified under Subparts 5-101, 5-102, and 5-103 shall be made available for a mobile facility, for a temporary food establishment without a permanent water supply, and for a food establishment with a temporary interruption of its water supply through:
|
||
5-2 PLUMBING SYSTEM Subparts 5-201 Materials 5-202 Design, Construction, and Installation 5-203 Numbers and Capacities 5-204 Location and Placement 5-205 Operation and Maintenance |
| Materials |
(A) A plumbing system and hoses conveying water shall be constructed and repaired with approved materials according to law. (B) A water filter shall be made of safe materials. |
|
|
|
|
|
| Design, Construction, and Installation |
(A) A plumbing system shall be designed, constructed, and installed according to law. (B) A plumbing fixture such as a hand washing facility, toilet, or urinal shall be easily cleanable.N
|
|
(A) A hand washing lavatory shall be equipped to provide water at a temperature of at least 43oC (110oF) through a mixing valve or combination faucet. (B) A steam mixing valve may not be used at a hand washing lavatory. (C) A self-closing, slow-closing, or metering faucet shall provide a flow of water for at least 15 seconds without the need to reactivate the faucet. (D) An automatic hand washing facility shall be installed in accordance with manufacturer=s instructions.
|
||
An air gap between the water supply inlet and the flood level rim of the plumbing fixture, equipment, or nonfood equipment shall be at least twice the diameter of the water supply inlet and may not be less than 25 mm (1 inch).
|
||
A backflow or backsiphonage prevention device installed on a water supply system shall meet American Society of Sanitary Engineering (A.S.S.E.) standards for construction, installation, maintenance, inspection, and testing for that specific application and type of device.
|
||
A water filter, screen, and other water conditioning device installed on water lines shall be designed to facilitate disassembly for periodic servicing and cleaning. A water filter element shall be of the replaceable type.
|
||
| Numbers and Capacities |
(A) Except as specified in && (B) and (C) of this section, at least 1 hand washing lavatory, a number of hand washing lavatories necessary for their convenient use by employees in areas specified under ' 5-204.11, and not fewer than the number of hand washing lavatories required by law shall be provided. (B) If approved and capable of removing the types of soils encountered in the food operations involved, automatic hand washing facilities may be substituted for hand washing lavatories in a food establishment that has at least one hand washing lavatory. (C) If approved, when food exposure is limited to packaged food and hand washing lavatories are not conveniently available, such as in some mobile or temporary food establishments or at some vending machine locations, employees may use chemically treated towelettes and/or approved hand sanitizers for hand washing. |
|
At least 1 toilet and not fewer than the toilets required by law shall be provided. If authorized by law and urinals are substituted for toilets, the substitution shall be done as specified in law. |
||
At least 1 service sink or 1 curbed cleaning facility equipped with a floor drain shall be provided and conveniently located for the cleaning of mops or similar wet floor cleaning tools and for the disposal of mop water and similar liquid waste.
|
||
5-203.14 Backflow Prevention Device, When Required.* A plumbing system shall be installed to preclude backflow of a solid, liquid, or gas contaminant into the water supply system at each point of use at the food establishment, including on a hose bibb if a hose is attached or on a hose bibb if a hose is not attached and backflow prevention is required by law, by:
|
||
|
||
Location and Placement |
A hand washing facility shall be located:
|
|
A backflow prevention device shall be located so that it may be serviced and maintained.
|
||
A water filter, screen, and other water conditioning device installed on water lines shall be located to facilitate disassembly for periodic servicing and cleaning.
|
||
Operation and Maintenance |
(A) A hand washing facility shall be maintained so that it is accessible at all times for employee use. (B) A hand washing facility may not be used for purposes other than hand washing. (C) An automatic hand washing facility shall be used in accordance with manufacturer=s instructions.
(A) Except as specified in 9 CFR 308.3(d) for firefighting, a person may not create a cross connection by connecting a pipe or conduit between the drinking water system and a non-drinking water system or a water system of unknown quality. (B) The piping of a non-drinking water system shall be durably identified so that it is readily distinguishable from piping that carries drinking water.N |
|
|
||
(A) A reservoir that is used to supply water to a device such as a produce fogger shall be:
(B) Cleaning procedures shall include at least the following steps and shall be conducted at least once a week:
A plumbing system shall be:
|
||
5-3 MOBILE WATER TANK AND MOBILE FOOD ESTABLISHMENT WATER TANK Subparts 5-301 Materials 5-302 Design and Construction 5-303 Numbers and Capacities 5-304 Operation and Maintenance |
| Materials |
Materials that are used in the construction of a mobile water tank, mobile food establishment water tank, and appurtenances shall be:
|
|
(C) Finished to have a smooth, easily cleanable surface. Design and Construction |
A mobile water tank shall be:
If a water tank is designed with an access port for inspection and cleaning, the opening shall be in the top of the tank and:
|
|
A fitting with "V" type threads on a water tank inlet or outlet shall be allowed only when a hose is permanently attached.
|
||
If provided, a water tank vent shall terminate in a downward direction and shall be covered with:
|
||
(A) A water tank and its inlet and outlet shall be sloped to drain. (B) A water tank inlet shall be positioned so that it is protected from contaminants such as waste discharge, road dust, oil, or grease.
A hose used for conveying drinking water from a water tank shall be:
|
||
Numbers and Capacities |
A filter that does not pass oil or oil vapors shall be installed in the air supply line between the compressor and drinking water system when compressed air is used to pressurize the water tank system.
|
|
A cap and keeper chain, closed cabinet, closed storage tube, or other approved protective cover or device shall be provided for a water inlet, outlet, and hose.
|
||
A mobile food establishment's water tank inlet shall be:
|
||
Operation and Maintenance |
A water tank, pump, and hoses shall be flushed and sanitized before being placed in service after construction, repair, modification, and periods of nonuse.
|
|
A person shall operate a water tank, pump, and hoses so that backflow and other contamination of the water supply are prevented.
If not in use, a water tank and hose inlet and outlet fitting shall be protected using a cover or device as specified under ' 5-303.12.
|
||
(A) Except as specified in & (B) of this section, a water tank, pump, and hoses used for conveying drinking water shall be used for no other purpose. (B) Water tanks, pumps, and hoses approved for liquid foods may be used for conveying drinking water if they are cleaned and sanitized before they are used to convey water.
|
||
5-4 SEWAGE, OTHER LIQUID WASTE, AND RAINWATER Subparts 5-401 Mobile Holding Tank 5-402 Retention, Drainage, and Delivery 5-403 Disposal Facility |
|
Mobile Holding Tank |
A sewage holding tank in a mobile food establishment shall be:
|
|
| Retention, Drainage, and Delivery design, construction, and installation |
Food establishment drainage systems, including grease traps, that convey sewage shall be designed and installed as specified under & 5-202.11(A).
(A) Except as specified in && (B) and (C) of this section, a direct connection may not exist between the sewage system and a drain originating from equipment in which food, portable equipment, or utensils are placed. (B) If allowed by law, a warewashing machine may have a direct connection between its waste outlet and a floor drain when the machine is located within 1.5 m (5 feet) of a trapped floor drain and the machine outlet is connected to the inlet side of a properly vented floor drain trap. (C) If allowed by law, a warewashing or culinary sink may have a direct connection.
|
|
location and placement |
(a) Every food establishment, restaurant or facility which has the potential to discharge waste water containing animal or vegetable fats, oils, grease or solids shall have installed the appropriate grease trap or interceptor device to prevent the discharge or concentration of such substances into the sewers. All such grease traps or interceptor devices shall be installed as set out in the Plumbing Code of Columbia, Missouri adopted in Section 6-52 of the Code of Ordinances of the City of Columbia, Missouri. (b) Every food service establishment, restaurant or facility required to have a grease trap or interceptor device shall develop a cleaning schedule and shall have such devices serviced, maintained, inspected and cleaned, at the establishment’s expense, as frequently as required to prevent discharge of grease into the sanitary sewers. The establishment shall maintain detailed records of such inspection and maintenance in a manner acceptable to the director of public works. Records will remain on file for at least three years. (c) Records required to be kept by this section shall be provided to health department inspectors during their periodic inspections and during the normal business hours of the establishment. (d) It shall be unlawful to fail to install, maintain, service or inspect the grease traps or interceptor devices required by this section, or to fail to keep the records required by this section, or to fail to allow the inspection of those records by City officials. |
|
| operation and maintenance |
Sewage shall be conveyed to the point of disposal through an approved sanitary sewage system or other system, including use of sewage transport vehicles, waste retention tanks, pumps, pipes, hoses, and connections that are constructed, maintained, and operated according to law.
|
|
Sewage and other liquid wastes shall be removed from a mobile food establishment at an approved waste servicing area or by a sewage transport vehicle in such a way that a public health hazard or nuisance is not created.
A tank for liquid waste retention shall be thoroughly flushed and drained in a sanitary manner during the servicing operation.
|
||
| Disposal Facility |
|
|
| design and construction |
Sewage shall be disposed through an approved facility that is:
|
|
Condensate drainage and other nonsewage liquids and rainwater shall be drained from point of discharge to disposal according to law. |
||
5-5 REFUSE, RECYCLABLES, AND RETURNABLES Subparts 5-501 Facilities on the Premises 5-502 Removal 5-503 Facilities for Disposal and Recycling |
Facilities on the Premises materials, design, construction, and installation |
If located within the food establishment, a storage area for refuse, recyclables, and returnables shall meet the requirements specified under '' 6-101.11, 6-201.11 - 6-201.18, 6-202.15, and 6-202.16.
An outdoor storage surface for refuse, recyclables, and returnables shall be constructed of nonabsorbent material such as concrete or asphalt and shall be smooth, durable, and sloped to drain.
|
|
If used, an outdoor enclosure for refuse, recyclables, and returnables shall be constructed of durable and cleanable materials.
|
||
(A) Except as specified in & (B) of this section, receptacles and waste handling units for refuse, recyclables, and returnables and for use with materials containing food residue shall be durable, cleanable, insect- and rodent-resistant, leakproof, and nonabsorbent. (B) Plastic bags and wet strength paper bags may be used to line receptacles for storage inside the food establishment, or within closed outside receptacles.
|
||
A refuse receptacle may not be located within a vending machine, except that a receptacle for beverage bottle crown closures may be located within a vending machine.
|
||
(A) Receptacles and waste handling units for refuse, recyclables, and returnables used with materials containing food residue and used outside the food establishment shall be designed and constructed to have tight-fitting lids, doors, or covers. (B) Receptacles and waste handling units for refuse and recyclables such as an on-site compactor shall be installed so that accumulation of debris and insect and rodent attraction and harborage are minimized and effective cleaning is facilitated around and, if the unit is not installed flush with the base pad, under the unit.
|
||
| numbers and capacities |
(A) An inside storage room and area and outside storage area and enclosure, and receptacles shall be of sufficient capacity to hold refuse, recyclables, and returnables that accumulate. (B) A receptacle shall be provided in each area of the food establishment or premises where refuse is generated or commonly discarded, or where recyclables or returnables are placed. (C) If disposable towels are used at hand washing lavatories, a waste receptacle shall be located at each lavatory or group of adjacent lavatories. |
|
A toilet room used by females shall be provided with a covered receptacle for sanitary napkins.
|
||
(A) Except as specified in & (B) of this section, suitable cleaning implements and supplies such as high pressure pumps, hot water, steam, and detergent shall be provided as necessary for effective cleaning of receptacles and waste handling units for refuse, recyclables, and returnables. (B) If approved, off-premises-based cleaning services may be used if on-premises cleaning implements and supplies are not provided.
|
||
| location and placement |
(A) An area designated for refuse, recyclables, returnables, and, except as specified in & (B) of this section, a redeeming machine for recyclables or returnables shall be located so that it is separate from food, equipment, utensils, linens, and single-service and single-use articles and a public health hazard or nuisance is not created. (B) A redeeming machine may be located in the packaged food storage area or consumer area of a food establishment if food, equipment, utensils, linens, and single-service and single-use articles are not subject to contamination from the machines and a public health hazard or nuisance is not created. (C) The location of receptacles and waste handling units for refuse, recyclables, and returnables may not create a public health hazard or nuisance or interfere with the cleaning of adjacent space.
|
|
| operation and maintenance |
Refuse, recyclables, and returnables shall be stored in receptacles or waste handling units so that they are inaccessible to insects and rodents. |
|
Storage areas, enclosures, and receptacles for refuse, recyclables, and returnables shall be maintained in good repair.
|
||
(A) Except as specified in & (B) of this section, refuse receptacles not meeting the requirements specified under & 5-501.13(A) such as receptacles that are not rodent-resistant, unprotected plastic bags and paper bags, or baled units that contain materials with food residue may not be stored outside. (B) Cardboard or other packaging material that does not contain food residues and that is awaiting regularly scheduled delivery to a recycling or disposal site may be stored outside without being in a covered receptacle if it is stored so that it does not create a rodent harborage problem.
Receptacles and waste handling units for refuse, recyclables, and returnables shall be kept covered:
|
||
Drains in receptacles and waste handling units for refuse, recyclables, and returnables shall have drain plugs in place.
|
||
A storage area and enclosure for refuse, recyclables, or returnables shall be maintained free of unnecessary items, as specified under ' 6-501.114, and clean.
|
||
(A) Receptacles and waste handling units for refuse, recyclables, and returnables shall be thoroughly cleaned in a way that does not contaminate food, equipment, utensils, linens, or single-service and single-use articles, and waste water shall be disposed of as specified under ' 5-402.14. (B) Soiled receptacles and waste handling units for refuse, recyclables, and returnables shall be cleaned at a frequency necessary to prevent them from developing a buildup of soil or becoming attractants for insects and rodents.
|
||
| Removal |
Refuse, recyclables, and returnables shall be removed from the premises at a frequency that will minimize the development of objectionable odors and other conditions that attract or harbor insects and rodents.
Refuse, recyclables, and returnables shall be removed from the premises by way of:
|
|
Facilities for Disposal and Recycling |
Solid waste not disposed of through the sewage system such as through grinders and pulpers shall be recycled or disposed of in an approved public or private community recycling or refuse facility; or solid waste shall be disposed of in an individual refuse facility such as a landfill or incinerator which is sized, constructed, maintained, and operated according to law.
|
Chapter Index: 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8